#railwayengineering
#DDS
#IRIfleetmonitor
We all know that "Fault in any 3-Phase Loco(WAP-5/WAP-7/WAG-9)" whether it is in Motion or Stand By Situation with PANTO Down and VCB Off Position is known as "DDS Information". This Fault can be related to Software used in these Locos or Hardware installed in these Locos.
In...
more... this Particular BLOG I am Sharing the following:
1 "DDS Information" of all RDS Locos TODAY Extracted in Excel Spreadsheet from IR Fleet Monitor Website(Excel Spreadsheet and also the Screenshot of the Download Link of the Excel Spreadsheet is attached )
2 "Number of Occurings of a DDS Info in any Particular Loco(In Times) Extracted in Excel Spreadsheet from IR Fleet Monitor Website(Excel Spreadsheet and also the Screenshot of the Download Link of the Excel Spreadsheet is attached )
For example: DDS Info "FLG1:0092-ACP/Train Part" occurs in WAG-9 of AQ Shed having Loco No 31099 : 14001 Times
DDS Info "HBB1:0010-Transformer pump 1 MCB open" occurs in WAP-7 of LGD Shed having Loco No 30262: 1479 Times
Please NOTE that we have ONLY 40 Locos (WAP-7/WAG-9/WAG-9H) having RDS installed in it. So in IRI Fleet Monitor website you will found DDS Information of these 40 Locos ONLY.NO WAP-5 has RDS installed as of now in IR. This IRI Fleet Monitor website is Designed & Maintained by Advanced Rail Controls Pvt. Ltd Bangalore, Forum please NOTE that the "Remote Diagnostic System" used in 3-Phase Locos is also manufactured by Advanced Rail Controls Pvt. Ltd Bangalore. Apart from RDS this Company also manufactures Driver Dispaly Unit and many other accessories of 3-Phase Locos and EMD Diesel Locomotives.